How to vent the radiator
With the advent of winter, the frequency of use of radiators gradually increases, but many users report that the radiators are not hot or have uneven heat dissipation. This is usually due to air trapped inside the radiator, preventing the hot water from circulating properly. This article will introduce in detail how to deflate the radiator, and attach relevant data and operation steps to help you solve the problem quickly.
1. Reasons why the radiator deflates

Air accumulation inside the radiator can cause the following problems:
| question | Reason |
|---|---|
| The radiator is not hot | Air blocking hot water circulation |
| Uneven heat dissipation | Air collects in localized areas |
| noise | Air movement produces abnormal noise |
2. Preparation work before deflation
Before you start deflating, you'll need the following tools:
| Tools | Purpose |
|---|---|
| deflate key | For unscrewing the air release valve |
| towel or container | catch the flowing water |
| screwdriver | Auxiliary operation (required for some radiators) |
3. Deflation steps
The following are detailed deflation steps:
| steps | Operating Instructions |
|---|---|
| 1. Turn off the heating system | Make sure the radiator is cool to avoid burns |
| 2. Find the bleed valve | Usually located on the top side of the radiator |
| 3. Place the container | Place a towel or container under the release valve |
| 4. Unscrew the air release valve | Turn the bleed key counterclockwise until you hear the sound of gas being released. |
| 5. Wait for the water flow to stabilize | When the gas is exhausted and the water flow is stable, close the valve clockwise |
| 6. Check the radiator | Turn the heating system back on and see if it returns to normal |
4. Precautions
During the deflation process, please pay attention to the following matters:
| Things to note | Description |
|---|---|
| avoid burns | Make sure the radiator is cool before operating |
| Prevent water leakage | When deflating, the water flow may be larger and needs to be properly caught. |
| Do not over twist | The air release valve is easily damaged and needs to be operated gently. |
5. Frequently Asked Questions
The following are the problems and solutions commonly encountered by users:
| question | solution |
|---|---|
| The air release valve cannot be opened | Spray a small amount of lubricant, or use pliers to assist |
| The radiator is still not hot after deflating the air | Check heating system pressure or contact a professional |
| Air release valve leaking | Replace the bleed valve or sealing ring |
6. Summary
Bleeding a radiator is a simple and effective way to solve the problem of a radiator that is not hot or dissipates heat unevenly. With the steps and precautions in this article, you can do it easily. If the problem is still not resolved, it is recommended to contact a professional maintenance personnel for further inspection.
I hope this article helps you enjoy a warm indoor environment during the winter months!